Aki
I'm having trouble understanding what you wrote below. It looks like the first one might be 1.30g for the motor. Then the length would be 1300/.260*10 = 50cm length. This would be around 20" which is close to what I normally use.
Is this correct?
----- Original Message -----
From: Akihiro Danjo
To: Indoor_Construction_at_yahoogroups.com
Sent: Friday, May 11, 2007 11:25 AM
Subject: Re: [Indoor_Construction] F1L motors
> I tend to use a brute force approach to sizing motors for the events
> that I fly. My F1L motors have been creeping up into the mid-.060 range.
> I was wondering if anyone would want to share info about the sizes
> they've had success with in high ceilings?
Bill san,
I do not know the rubber width at all because I have never measured the
width of rubber.
I have used 260 to 275 mg/ 10cmLoop (= 1.30 to 1.38 g/m) in high ceilings
and 270 to 300 mg/ 10cmLoop in low ceilings for my F1Ls.
Good flying, Aki
[Non-text portions of this message have been removed]
Received on Fri May 11 2007 - 09:50:35 CEST
This archive was generated by Yannick on Sat Dec 14 2019 - 19:13:45 CET