RE: RE: RE: Re: RE: Re: Generally accepted good winding technique?
Yes, yes, and yes :)
---In Indoor_Construction_at_yahoogroups.com, <indoor_construction_at_yahoogroups.com> wrote:
New formulas for an amateur like me. Questions:
max turns = motor_length * 45.67*SQRT (motor_length / motor_weight )
motor_length in inch or millimeters ? Guess inch ?
motor_length for loop or rubber ? Guess loop ?
motor_weight in grams ?
max torque =( motor_weight / motor_length / 0.11)^1.5
Rolf
---In indoor_construction_at_yahoogroups.com, <ykleetx_at_...> wrote:
I wind to targets in turns and torque. But both are only guidelines. Whereas I have noticed that 5/99 yields consistently 7% more turns than the formula, I have not kept track as carefully the torque.
---In Indoor_Construction_at_yahoogroups.com, <indoor_construction_at_yahoogroups.com> wrote:
On 09-Oct-13 02:28, ykleetx_at_... mailto:ykleetx@... wrote:
>
> I haven't tried to extrapolate the max torque. Anything over the
> predicted maximum is a gift, and I have refrained from looking at it
> too closely :)
>
>
So you wind for target turns then, not target torque?
-Tapio-
Received on Wed Oct 09 2013 - 10:43:26 CEST