Hi Lauren.
No, there is not enough force for that. The actuator arms 'lock' the blades/holders in place. There is only a tiny bit of movement outwards and maybe 20 degrees or so rotationally during the torque/pitch change.
Regards.
Mike Kirda
--- In Indoor_Construction_at_yahoogroups.com, "lauren.rezac" <lauren.rezac@...> wrote:
>
> Tom,
>
> How do the hinges stay on the shaft? Is it the wire that go through the torque arm? I would think the centrafugial force of the blades would force the hinges off of the shaft.
>
> Thanks,
>
> Lauren