Re: prop pitch

From: Bill Gowen <b.gowen_at_comcast.net>
Date: Thu, 27 Aug 2009 19:33:59 -0400

No. You need to read down the appropriate column (4" for LPP) to 18.9 then go to the left to read the angle which is 37 degrees. Put the prop holder in the end of the gage with 3 holes, put the adjustable part in the set of holes that are 4" from the end ones and set the blade angle at that point to 37 degrees.

  ----- Original Message -----
  From: barrysholder
  To: Indoor_Construction_at_yahoogroups.com
  Sent: Thursday, August 27, 2009 7:28 PM
  Subject: [Indoor_Construction] prop pitch


    While building my serious LPP "Thrush" on the plans for the prop, it calls for 19" pitch. I am assuming that using my F1D.biz gauge that would be 19 deg. Is that correct?



  


------------------------------------------------------------------------------



  No virus found in this incoming message.
  Checked by AVG - www.avg.com
  Version: 8.5.409 / Virus Database: 270.13.70/2329 - Release Date: 08/27/09 08:11:00
Received on Thu Aug 27 2009 - 16:34:19 CEST

This archive was generated by Yannick on Sat Dec 14 2019 - 19:13:45 CET