RE: RE: Units of measurement?
> 1. The GA (Goldstein Adjustment) has nothing to do with thickness
> variations. Euler doesn't discriminate. This is BS (Blowing
> Smoke). The adjustment has everything to do with pricing, and
> moving less desirable wood. I pointed out this complication
> before TWIB went public.
Bruce, if you read code, here is the adjustment. Humm, works on thickness.
Guess it just proves you are still clueless.
{1/2002 TG modification to adjust thick wood from same block to give similar
values as thin wood}
IF Thickness > 0.05 Then
Modulus := (1 + (2*Thickness))*
(0.188*length*length*(buckleload-woodweight)/(WoodWidth*thickness*thickness*
thickness))
Else
Modulus :=
0.188*length*length*(buckleload-woodweight)/(WoodWidth*thickness*thickness*t
hickness);
{Elastic modulus (gr per square cm) }
Stiffness:= (Modulus*2500)/(density*density*13000000);
Tim
[Denver, CO]
Jones design balsa stripper now available!!
Indoor balsa wood & supplies
Now carrying Carbon Plate, rod, tube, and strip.
www.F1D.biz
Indoor flying info
www.IndoorDuration.com
Received on Sat Apr 01 2006 - 08:09:31 CEST